Anhang | ASCII Communication with Sensor
optoNCDT 1750
A 3.2.1.9
TERMINATION
TERMINATION OFF | ON
§Activation of a terminating resistor in synchronization instruction
Switches off/on the termination resistor at the Sync/Trig synchronization input in order to avoid reflection.
OFF: no terminating resistor
ON: with terminating resistor
A 3.2.2
User Level
A 3.2.2.1
LOGIN, Change of the User Level
LOGIN <Password>
Enter the password to switch to a different user level. The following user levels exist:
- USER (standard user): “read-only” access to all elements and graphical display of output values of web
interface
- PROFESSIONAL (Expert): Read/write access to all elements
A 3.2.2.2
LOGOUT, Change into User Level
LOGOUT
Sets the user level to USER.
A 3.2.2.3
GETUSERLEVEL, User Level Request
GETUSERLEVEL
Request the current user level.
A 3.2.2.4
STDUSER, Set Standard User
STDUSER USER|PROFESSIONAL
Sets the standard user, who is logged in after system start. Standard user does not change with LOGOUT,
i.e. login as standard user is done automatically after the command RESET or power supply of sensor is
switched on.