Seite 116
Anhang | ASCII Communication with Sensor
optoNCDT 1750
A 3.2.3.4
TRIGGERAT, Effect of the Trigger Input
TRIGGERAT INPUT | OUTPUT
- INPUT:
Triggering the measured value recording. When calculating the mean, measured values
immediately before the trigger event are not included; instead older measurement values are used, which
were output in previous trigger events.
- OUTPUT:
Triggering the measurement value output. When calculating the mean, measured values
immediately before the trigger event are used.
A 3.2.3.5
MFILEVEL, Input Level Multi-Function Input
MFILEVEL HTL|TTL
Selection of switching or trigger level for the multi-function input
- HTL: Input expects HTL level
- TTL: Input expects TTL level
A 3.2.3.6
TRIGGERCOUNT, Number of Output Measurement Values
TRIGGERCOUNT INFINITE | <n>
<1...16382>
Number of Output Measurement Values with Triggering
- INFINITE: Start of continuous output after the first trigger event
- <n>: Number of measured values to be output after every trigger event n = 1 …16382.
A 3.2.3.7
TRIGGERSW, Software Trigger Pulse
TRIGGERSW SET|CLR
Generates a software trigger pulse.
- SET: Generates one single trigger pulse when edge triggering (EDGE) is active. Continuously generates
trigger pulses with level triggering (PULSE)
- CLR: Stops trigger pulses with level triggering (PULSE). With edge triggering, an ongoing task is aborted.
Abortion is also possible when selecting the trigger sources MFI and SyncIO.
Summary of Contents for optoNCDT 1750
Page 139: ......