Seite 118
Anhang | ASCII Communication with Sensor
optoNCDT 1750
A 3.2.4.5
ERRORLIMITVALUES1/2
ERRORLIMITVALUES1 [<lower limit [mm]> [<upper limit [mm]>]]
ERRORLIMITVALUES2 [<lower limit [mm]> [<upper limit [mm]>]]
Defines the lower and upper limit value for the switching outputs.
Value range:
- <lower limit [mm]> = (-2 ... 2) * measuring range [mm]
- <upper limit [mm]> = (-2 ... 2) * measuring range [mm]
A 3.2.4.6
ERRORHYSTERESIS
ERRORHYSTERESIS <hysteresis
[mm]
>
Value by which the measured value must fall short of the limit value to deactivate the switching output.
Value range: 0 ... 2 * measuring range [mm].
A 3.2.4.7
ERROROUTHOLD
ERROROUTHOLD <hold period>
Indicates in ms how long the switching output must be active at least when the limit value is exceeded. This
time period starts when the limit value is exceeded. Range: 0….1000 [ms].
A 3.2.5
Handling of Setups
A 3.2.5.1
IMPORT
IMPORT [FORCE] [APPLY] <ImportData>
Import of data in JSON format to the sensor.
First, the import command returns a prompt (->). Afterwards, data can be sent. After importing a prompt
(->) is returned.
- FORCE: Overwriting measurement settings (=MEASSETTINGS) with the same name (otherwise an error
message is displayed when the name is the same). When importing all measurement settings or device
settings (= BASICSETTINGS) FORCE must always be stated.
- APPLY : Activates the settings after importing / reading the Initial Settings.
- ImportData: Data in JSON format
Summary of Contents for optoNCDT 1750