Setting Sensor Parameters
optoNCDT 1750
7.4.7
Error Processing
The error processing controls the behavior of the analog output and the RS422 interface in the event that an
error occurs.
Error handling
Digital output, no value
The analog output supplies 3 mA resp. 5.2 / 10.2 V
instead of measurement value. The RS422 interface
outputs an error value.
Hold last value infinite
Analog output and RS422 interface stop at the last
valid value.
Hold last value
1 ... 1024
Value
If no valid reading can be obtained, an error is issued. Should this be a problem for processing, the last valid
value can be hold for a certain period of time, and will be issued repeatedly. After this period has expired, an
error value is output.
Grey shaded
fields require a
selection.
Value
Dark-bordered
fields require
you to specifie
a value.