Page 72
Setting Sensor Parameters
optoNCDT 1750
7.6.2.2
Behavior of the Digital Output
Master values based on the zeroing or master function are coded with 18 bits. Master value range: 0 ... 2x measuring range. The
examples demonstrate the behavior of the digital value with an ILD1750-100, measuring range 100 mm.
Target with 16% of the measuring range
Target with 60% of the measuring range
Target with 60% of the measuring range
SMR
EMR
0 %
16 %
100 % MR
Target
108718
16.00 mm
sensor off
RS422 on
output off
analog on
opto
NCDT
SMR
EMR
0 %
60 %
100 % MR
Target
137554
60.00 mm
sensor off
RS422 on
output off
analog on
opto
NCDT
SMR
EMR
0 %
60 %
100 % MR
Target
137554
60.00 mm
sensor off
RS422 on
output off
analog on
opto
NCDT
Zero setting (master value = 0 mm)
Zero setting (master value = 0 mm)
Setting master value 10 mm
SMR
EMR
0 %
16 %
100 % MR
Target
98232
0.00 mm
87746
-16.00 mm
153282
84.00 mm
sensor off
RS422 on
output off
analog on
opto
NCDT
EMR
EMR
0 %
60 %
100 % MB
Target
98232
0.00 mm
58910
-60.0 mm
124446
40.00 mm
sensor off
RS422 on
output off
analog on
opto
NCDT
EMR
SMR
0 %
60 %
100 % MR
Target
104786
10.00 mm
65464
-50.0 mm
131000
50.00 mm
sensor off
RS422 on
output off
analog on
opto
NCDT