Installation and Assembly
combiSENSOR 64x0
4.
Installation and Assembly
4.1
Precautionary Measures
No sharp-edged or heavy objects may come into contact with the sensor cable sheath.
In pressurised rooms the cable must be protected against pressure loads.
The minimum bending radius is 20 mm (.79 inch). Kinks must be avoided at all cost.
The connections must be checked for tight fit.
i
A damaged cable cannot be repaired.
4.2
Sensor
When assembling, make sure that the polished sensor surface is not scratched.
i
The target must not touch the sensor surface. Comply with the working distance.
ø 30 (1.18)
KSH5
5
(.20)
26
(1.02)
37
(1.46)
5
(.20)
26
(1.02)
37
(1.46)
Mounting
area
KSH10
ø 45 (1.77)
5
5 (0.20)
Measuring
direction
Fig. 5 Sensor dimensions
Fig. 6 Free space with no
metallic
conductive objects
Make sure when assembling the sensor that there are no metallic conductive objects within the gray
marked area, see
Fig. 6
. Else the linearity may be changed of the eddy current sensor by up to about 1
% of measuring range.
Legend