Ethernet Interface
combiSENSOR 64x0
6.5.4
Trigger Mode
This menu item determines the trigger behavior. The triggering is released by an external electrical signal, see
Chap.
4.6.2
or by the command $ GMD, see Chap.
6.4.3
.
If the trigger mode is turned off, the combiSENSOR 64x0 will send the measuring values without interruption
and with the adjusted data rate.
Trigger mode
Rising edge
A measuring value is output per edge.
High level
Level triggering. Measuring value output, as long as the level is active.
Gate rising edge
Starts resp. stops the measuring value output alternatively.
Off
Controller sends measuring values continuously.
6.5.5
Data Rate
Data Rate
2.6 / 5.21 / 10.42 / 15.63 / 26.04 / 31.25 / 52.08 / 62.5 /
104.2 / 520.83 / 1041.67 / 2083.33 / 3906.25 Sa/s
Instructs the sensor about the
frequency, with which data are
output via the Ethernet interface.
6.5.6
Filter, Averaging
Average type
Off
Moving
Value
Value range 2 / 3
/ 4 / 5 / 6 / 7 / 8
Designation of averaging type.
Averaging number indicates,
about how many current measu-
ring values should be averaged
in the controller, before a new
measuring value is output.
Arithmetic
Value
Median
Value
Dynamic noise rejection
It is recommended, to use averaging for statical measuring or slowly changing measuring values. An avera-
ging reduces noise or suppresses distortions in measuring values.