Page 38
Ethernet Interface
combiSENSOR 64x0
6.4.2
Trigger Mode (TRG)
There are three possible settings regarding the trigger input, see Chap.
5.3
.
Irrespective of the trigger mode set, a single measured value per channel can be called up by means of a
software command, see Chap.
5.4.3
. If the trigger mode is turned off, the combiSENSOR 64x0 will send the
measurement values without interruption and with the adjusted data rate.
TRG
Command
$TRGn<CR>
Response
$TRGnOK<CRLF>
Index
n = 0: Continuous transmission (default setting)
n = 1: Triggermode 1 (rising edge)
n = 2: Triggermode 2 (high level)
n = 3: Triggermode 3 (gate rising edge)
? = Request trigger mode
Request Trigger mode
Command
$TRG?<CR>
Response
$TRG?nOK<CRLF>
6.4.3
Get Measured Data (GMD)
In the trigger mode, one measuring value is transmitted per channel.
GMD
Command
$GMD<CR>
Response
$GMDOK<CRLF> + Measuring value in binary mode (format as in
operating mode “continuous transmission”) via data port