background image

MICRO-EPSILON Eltrotec GmbH
Manfred-Wörner-Straße 101 · 73037 Göppingen / Germany  
Tel. +49 (0) 7161 / 98872-300 · Fax +49 (0) 7161 / 98872-303 
[email protected] · www.micro-epsilon.com
Your local contact: 

www.micro-epsilon.com/contact/worldwide/

CFO100
CFO200 

Operating Instructions

color

SENSOR

 CFO

Summary of Contents for colorSENSOR CFO

Page 1: ...Stra e 101 73037 G ppingen Germany Tel 49 0 7161 98872 300 Fax 49 0 7161 98872 303 eltrotec micro epsilon com www micro epsilon com Your local contact www micro epsilon com contact worldwide CFO100 CF...

Page 2: ...paque transparent and self luminous objects MICRO EPSILON Eltrotec GmbH Manfred W rner Stra e 101 73037 G ppingen Deutschland Tel 49 0 7161 98872 300 Fax 49 0 7161 98872 303 e mail eltrotec micro epsi...

Page 3: ...16 2 5 1 General 16 2 5 2 Color Processing 16 2 6 Technical Data CFO100 17 2 7 Technical Data CFO200 19 2 8 Display Elements 21 3 Delivery 22 3 1 Unpacking Included in Delivery 22 3 2 Storage 22 4 In...

Page 4: ...ions 58 5 3 7 1 IN0 Switching Input Function Assignment 59 5 3 7 2 Hold Time 61 5 3 7 3 Multi Teach Mode 62 5 3 7 4 Tolerance Mode 63 5 3 7 5 Conclusion of Option Settings Save or Quit 65 5 3 8 Key Lo...

Page 5: ...Add Color Group 97 5 6 5 2 Teaching and Editing Colors 98 5 6 5 3 Deleting Colors Color Table 103 5 6 6 Trigger Input 104 5 6 7 Outputs 109 5 6 8 System Settings 111 5 6 8 1 Select Language 112 5 6 8...

Page 6: ...colorSENSOR CFO Appendix A 1 Optional Accessories 128 A 2 Factory Settings 135 A 3 Interface Instructions 136...

Page 7: ...Page 7 colorSENSOR CFO...

Page 8: ...Page 8 colorSENSOR CFO...

Page 9: ...display output device according to the safety regulations for electrical equipment Risk of injury Damage to or destruction of the controller or the measuring system The supply voltage must not exceed...

Page 10: ...es 1 4 Intended Use The colorSENSOR CFO is designed for use in an industrial environment It is used for Relative color measurement or inspection Intensity measurement Completeness check presence and a...

Page 11: ...Storage 10 85 C 14 185 F Humidity 20 80 relative humidity non condensing Ambient pressure Atmospheric pressure The controller can be used in a wide temperature range and is stable When all sockets ar...

Page 12: ...ows fixation using the dovetail principle A mounting adapter DIN rail mounting kit for DIN rail mounting is available separately 2 2 Measuring Principle The measuring system for relative color measure...

Page 13: ...s With the colorSENSOR CFO you can measure the following color spaces XYZ xyY L a b L u v L u v i For more details on color spaces please refer to https www micro epsilon com download products dat Bas...

Page 14: ...olerance space Sphere Fig 3 Tolerance space Cylinder Fig 4 Tolerance space Box C1 learned color 1 Cm detected color For an evaluation of color deviations the color tolerance parameters should be based...

Page 15: ...pace Cylinder tolerance values are set and evaluated separately for the bright ness value L and the color values a b i Tolerance space Cylinder is useful if higher distance variants are present during...

Page 16: ...displays REST API described in Interface Instructions see A 3 RS232 described in Interface Instructions see A 3 Trigger inputs Signaling monitoring of recognition results via Switching outputs all in...

Page 17: ...depending on number of colors learned and setting for averaging Temperature stability 0 1 FSO K Light source White light LED 425 750 nm AC operation luminous flux at 1 kHz 130 lm adjustable or OFF fo...

Page 18: ...s each Protection class DIN EN 60529 IP65 when connected Material Aluminum black anodized Weight approx 200 g Compatibility with all CFS sensors 4 Control and indicator ele ments Operation via keypad...

Page 19: ...g on number of colors learned and setting for averaging Temperature stability 0 1 FSO K Light Source White light LED 425 750 nm AC operation luminous flux at 1 kHz 220 lm adjustable or OFF for primary...

Page 20: ...in 3 axes 10 cycles each Protection class DIN EN 60529 IP65 when connected Material Aluminum black anodized Weight approx 200 g Compatibility with all CFS sensors 4 Control and Indicator Ele ments Ope...

Page 21: ...plays indicate the following information Operating mode ON OFF Current state of switching outputs Key lock Selected submenu The following settings are visible depending on the submenu selected LED int...

Page 22: ...aging and ensure that the goods are forwarded in such a way that no damage can occur Check the delivery for completeness and shipping damage immediately after unpacking If there is damage or parts are...

Page 23: ...vel surface or fastened with the dovetail on the rear of the controller i Position the controller so that the connections controls and displays are not concealed We recommend maintaining a clearance o...

Page 24: ...9 50 1 97 2 08 25 98 24 94 15 1 94 19 7 78 R 0 3 M18x1 11 43 13 51 31 1 22 61 2 40 7 25 29 13 51 M12x1 Fig 6 colorSENSOR CFO100 CFO200 dimensional drawing dimensions in mm inches NOTICE Do not allow t...

Page 25: ...ed in the chapter Mem brane Keys see 5 2 The following table provides an overview of the individual controls Key Meaning Location TEACH AUTO Teach Automatic modulation INT Illumination intensity Enter...

Page 26: ...right corner for key indication There are two status LEDs on the top right of the front panel The LEDs can assume the following states Switched off Continuously illuminated Various flashing rhythms L...

Page 27: ...2 OUT5 corresponds to LED6 OUT2 corresponds to LED3 OUT6 corresponds to LED7 OUT3 corresponds to LED4 OUT7 corresponds to LED8 The options are located on the left of the eight output indicators see Fi...

Page 28: ...200 Fig 11 Electrical connections on colorSENSOR CFO200 1 SYS System Power PLC Power supply switching outputs switching input RS232 2 ETH Ethernet Connection to PC 3 I O Digital I O PLC CFO200 only Sw...

Page 29: ...l input the process RS232 interface and three digital outputs directly to a PLC 8 pin plug 24 VDC 15 Imax 500 mA not electrically separated polarity reversal protection GND is electrically connected t...

Page 30: ...transmitting measured values via REST API described in the Interface Instructions see A 3 4 pin socket with Ethernet network PC Connect the controller to the network using a shielded Ethernet cable Ca...

Page 31: ...aluation unit All GND conductors are interconnected with one another and to the supply voltage ground Use a shielded cable with a length 30 m Micro Epsilon recommends the optionally available CAB M12...

Page 32: ...to the evaluation unit All GND conductors are interconnected with one another and to the supply voltage ground Use a shielded cable with a length of max 5 m Micro Epsilon recommends the optionally av...

Page 33: ...escription Comment 1 White IN0 Switchable via keypad trigger input measurement trigger or learn color Configurable via web page measurement trigger learn color learn color as new group add color to cu...

Page 34: ...table automatic controller sensitivity adjustment white balance key lock Not electrically separated compara tor input with threshold at V 2 5 low level V 2 5 high level V 2 5 max 30 V internal pull d...

Page 35: ...V The switching outputs are protected against polarity reversal overload 100 mA excessive temperature and have an integrated self induction recuperation diode for inductive loads Not electrically sep...

Page 36: ...rogrammed detected color or color group directly or in binary code Not electrically separated 24V logic HTL low level GND high level V Imax 100 mA 5 Gray OUT4 6 Pink OUT5 7 Blue OUT6 8 Red OUT7 i Swit...

Page 37: ...The coding on the sensor connector CFS or FA is on the side of the illumination LED Keep the end surfaces of the sensor free of dust avoid any damage or soiling e g by touching This also ap plies to...

Page 38: ...e integrated optical fiber As the sensor optical fiber consists of a glass fiber bundle with several individual fibers a break in the illu mination fibers causes a drop in the illumination intensity a...

Page 39: ...Connect the controller to the sensor optical fiber see 4 4 Fig 20 Overall view of CFO controller with CFS sensor Connect the controller to a power supply see 4 3 1 Switch on the power supply After sw...

Page 40: ...n for color is not detected In the delivery state all outputs are set to high when no color is detected This basic setting can be changed via the REST API described in the Interface Instructions see A...

Page 41: ...rface see 5 5 network interface or serial interface for initial setup 5 3 Membrane Keys The keypad has a number of keys and LEDs The most important settings and controller operations can be activated...

Page 42: ...t The key label indicates the operating function when the key is depressed for a longer period e g a menu The label below the key indicates the short key actuation available within a menu The key assi...

Page 43: ...longer All descriptions start in the operating mode If no learned color is currently recognized the following repre sentation typically applies The sensor is in the operating mode In the delivery stat...

Page 44: ...2 sec one of the keys to enter different menus from the operating mode After 2 seconds the key LED will start flashing to indicate that it has been pressed long enough Menu mode Submenu Except for th...

Page 45: ...change in the optical conditions such as Distances Alignment Lenses Sensor replacement Match the intensity settings of the system to the brightest object expected i Each time the optical conditions ar...

Page 46: ...uation Here the modulation of the receiver is adjusted so that it detects enough light but not too much standard setting 80 The controller internally sets the best combination of measurement averaging...

Page 47: ...s 1 8 flash alternately i e the even LEDs and the odd LEDs alternately flash together between on and off i The automatic modulation sets the photo receiver to 80 saturation INT OPT ESC TOL CLR TEACH A...

Page 48: ...INT OPT ESC TOL CLR TEACH AUTO 1 2 3 4 5 6 7 8 OPTIONS OUT LEVEL GATE TEACH HOLD MULTI CLASSIFY CYLINDER SPHERE BOX Press the key for less than 2 sec If a lower modulation is desired press the key fo...

Page 49: ...I CLASSIFY CYLINDER SPHERE BOX Save Press the Enter key for longer than 2 sec The results of the modulation are saved The display returns to the operating mode To quit Press the ESC key for longer tha...

Page 50: ...ASSIFY CYLINDER SPHERE BOX The switching outputs of the selected recognition groups flash rhythmically The flashing rate indicates the status of the current recognition group Medium fast flashing indi...

Page 51: ...h function is that changes in the distance or angle of the test specimens can be stored as a separate color in the same color group thus increasing process reliability The 1 out of N codes are easily...

Page 52: ...long as the TEACH key is held down The first color is learned after a long actuation time any further color is learned every second 1 Hz The key LED flashes briefly 100 ms for each color learned 5 3 4...

Page 53: ...ognized all outputs on is displayed depending on whether or not the last color learned is still beneath the sensor Quit Press the ESC key for longer than 2 sec to discard all changes to the color tabl...

Page 54: ...put LEDs 1 8 output the set output configuration signal for No color rec ognized By default 3 output LEDs are illuminated with the CFO100 8 output LEDs with the CFO200 Quit Press the ESC key for more...

Page 55: ...x Tolerance stage DErel L ab L a b 1 0 3 0 6 0 3 0 6 0 3 0 3 2 0 5 1 0 0 5 1 0 0 5 0 5 3 1 0 2 0 1 0 2 0 1 0 1 0 4 2 0 4 0 2 0 4 0 2 0 2 0 5 4 0 8 0 4 0 8 0 4 0 4 0 6 6 0 12 0 6 0 12 0 6 0 6 0 7 8 0 1...

Page 56: ...EACH AUTO 1 2 3 4 5 6 7 8 OPTIONS OUT LEVEL GATE TEACH HOLD MULTI CLASSIFY CYLINDER SPHERE BOX Press the TOL key for less than 2 sec to enter the tolerance submenu INT OPT ESC TOL CLR TEACH AUTO 1 2 3...

Page 57: ...GATE TEACH HOLD MULTI CLASSIFY CYLINDER SPHERE BOX Press the key for less than 2 sec to decrease the color tolerance The changed color tolerance stage is displayed Press the TEACH key for less than 2...

Page 58: ...e currently selected GATE option triggered color evaluation and or TEACH is indicated by flashing The indicators for the selected option are visualized by flashing whereby 1900 100 ms indicates ON and...

Page 59: ...LEDs flash slowly 100 1900 ms As soon as a function is selected the set function flashes rapidly 1900 100 ms Triggered color evaluation GATE If the triggered color evaluation gate is active the contro...

Page 60: ...luation is switched on via IN0 INT OPT ESC TOL CLR TEACH AUTO 1 2 3 4 5 6 7 8 OPTIONS OUT LEVEL GATE TEACH HOLD MULTI CLASSIFY CYLINDER SPHERE BOX Press the TEACH key for less than 2 sec to switch the...

Page 61: ...n of LED display 1 0 ms 1x flashing with 150 150 ms followed by 900 ms off 1200 ms 2 10 ms 2x flashing with 150 150 ms followed by 600 ms off 1200 ms 3 1000 ms 3x flashing with 150 150 ms followed by...

Page 62: ...number of colors quickly in one color group The colors continue to be learned as long as the TEACH key is held down The first color is learned after the long actuation time greater than 2 seconds and...

Page 63: ...ultiple teach mode The LED flashes rapidly 1900 100 ms to signal that the multi teach mode is activated 5 3 7 4 Tolerance Mode Changing the tolerance mode is useful if your application requires specif...

Page 64: ...for less than 2 sec to switch to the next tolerance mode The LED then flashes rapidly to signal the tolerance mode selected Press the TEACH key for less than 2 sec again to switch to the next toler a...

Page 65: ...r than 2 sec to discard changes to the settings and return to the operating mode without saving 5 3 8 Key Lock The keys can be locked using a key combination to prevent unauthorized settings The key l...

Page 66: ...n of the controller If you have configured your browser so that it accesses the Internet via a proxy server please add the IP address of the controller 169 254 168 150 in the browser settings to the l...

Page 67: ...art of web interface Click on the button with the magni fying glass icon The program searches the available interfaces for connected colorSENSOR CFO controllers You need an HTML5 compatible web browse...

Page 68: ...settings click on the Change IP Address button Address type static IP address IP address 169 254 168 150 1 Subnet mask 255 255 0 0 Click on the Change button to transmit the changes to the controller...

Page 69: ...ss from your IT department Start the sensorTOOL program see 5 4 1 Click the button Now select the desired controller from the list Click on the Start Browser button to connect the controller to your s...

Page 70: ...5 5 Web Interface Launch the web interface of the color measuring system see 5 4 2 Interactive web pages for programming the controller now appear in the web browser Fig 26 First interactive web site...

Page 71: ...r descriptions and tips on filling in the website or configuring the controller The controller is active and supplies measurement values The currently running measurement can be con trolled using the...

Page 72: ...uage setting in your control system PC is taken over in the basic System settings You can choose German English Chinese Japanese and Korean as web interface language Fig 27 Language selection The foll...

Page 73: ...ble at 3 or 8 outputs Here 1 corresponds to OUT0 and 8 to OUT7 on the SYS connector see 4 3 1 and the I O socket When the output is switched to LOW white is displayed and when switched to HIGH green i...

Page 74: ...put Color not recognized 0 Hold time for the output Color not recognized Color table Displays the number of learned color groups and the total number of learned colors that you have taught in under th...

Page 75: ...e browser as HTML5 where they continue to run autono mously while the controller continues to operate independently i If you allow the diagram display to run in a separate browser tab or window it is...

Page 76: ...d timeline Add new color group 1 2 3 255 Adds a new color group also see Home see 5 5 1 menu and Settings see 5 6 menu Diagram selection Timeline L a b View can be set individually see Fig 31 see Fig...

Page 77: ...with a point as decimal separator i Only a limited number of recorded measure ments can be stored about 50 000 If more readings are saved the oldest readings are deleted Displays XYZ xyY L a b L u v L...

Page 78: ...the accuracy of the display medium the coloring of the displayed tolerance ranges approximates the color values acquired by the controller RGB cannot represent all real colors However since most displ...

Page 79: ...individual diagrams can also be displayed separately 5 5 4 2 Timeline Select the Measurement Timeline menu Now a measurement recording starts depending on the runtime when the diagram is activated sta...

Page 80: ...ng an ongoing measurement The area with dark background defines the view and thus the time range for the upper three diagrams You can shift or change the size of this dark area with the mouse by holdi...

Page 81: ...n to the color values of the color currently detected by the measuring system is displayed in the color circle 2 The current color values are located on the right next to the color display 3 If a colo...

Page 82: ...ware webpage version and MAC address of the used controller In the left info bar you will find our contact details for your support request if you need help with the controller or the interface Fig 34...

Page 83: ...via the controller web interface see 5 5 with API command set and terminal program via RS232 or MEDAQLib described in the Interface Instruc tions see A 3 i After programming save all settings permane...

Page 84: ...etection profile Automatic modula tion White reference Color group see 5 5 2 Distance model Hold time Color table see 5 6 5 Number of color groups Trigger input see 5 6 6 Level High Level Low Rising e...

Page 85: ...ofile Go to the menu Settings Detection profile Fig 36 Detection profile window In the detection profile you can set and save the basic settings for the colorSENSOR CFO such as color space measurement...

Page 86: ...rofile 0 L a b 1 L a b 9 XXX Allows for the detection profiles setups to be created deleted and switched Supports up to ten detection profiles When adding a detection profile a name with n 1 color spa...

Page 87: ...4 characters long and contain only alphanu meric characters a z A Z 0 9 no umlauts spaces and the special characters Color space defines the color space to be used for detec tion Changing the color sp...

Page 88: ...nal controller parameters for the current optical situation The modulation of the receiver is adjusted so that it detects enough but not too much light default setting 80 The controller internally set...

Page 89: ...can be between 0 01 and 10 000 Hz for the CFO100 and 30 000 Hz for the CFO200 LED On The internal LED and ambient light compensation can be switched off or on for testing self luminous objects OFF Com...

Page 90: ...40 White reference White refer ence Current white refer ence User specific Reset Displays the currently used white refer ence It is possible to set a customized white reference which overwrites the fa...

Page 91: ...ectly in the controller and does not have to be saved sepa rately in a setup If the white balancing process fails the previous white balance continues to be used i You should perform an automatic modu...

Page 92: ...limits depending on the tolerance model and hold times for output configuration can be set i These parameters are applied for every new color group added When these parameters are changed color groups...

Page 93: ...refer to see 2 4 Fig 42 Distance model Distance model Distance model Classification Set the tolerance assessment that is used for new color groups The following dis tance models can be set Classificat...

Page 94: ...of 33 s Downstream processing can often only handle processes with a change in the ms range For this purpose the hold time is used to output the state at the output of the detected color e g for 5 ms...

Page 95: ...colors are assigned to the color groups and thus to the output configuration In the color table the color name the distance model the tolerance sizes and the hold time can be custom ized for each col...

Page 96: ...Page 96 Operation colorSENSOR CFO Fig 45 Settings Color table menu...

Page 97: ...new color group to teach the current color detected by the sensor with your own output configuration tolerance model tolerance values and hold time The settings applied correspond to the ones selecte...

Page 98: ...me for the switching outputs Teaching colors Teaches current color 1 and adds it to the corresponding color group memory see Fig 47 Edit Allows editing and setting the color group 2 The settings of a...

Page 99: ...Teach menu using the keypad on the controller see 5 3 4 1 Recently taught colors are also stored after switching off the controller 2 Allows you to change and set the color group parameters for the se...

Page 100: ...the selected color space are displayed and can also be edited The color space can be changed in the detection profile see 5 6 3 1 10 The output configuration defines the outputs to be switched upon r...

Page 101: ...eters are set for Classify because the currently measured color is always asso ciated to the color saved in the color table with the smallest distance to the measured color see 2 4 When teaching a new...

Page 102: ...two decimal places 9 a b 130 130 Value X Y Z 0 130 Value Output Binary 1 8 or 1 255 high Selected by clicking the outputs for binary or direct coding blue is set to high white is set to low low Hold...

Page 103: ...the button located to the right of the Auto Reset parameter see Fig 48 2 You can remove a single color from the table using the button located directly to the right of the corresponding color values...

Page 104: ...sed for the following purposes Switching outputs teaching or removing colors or color groups removing color table running autogain automatic modulation of the receiver or activating key lock Each trig...

Page 105: ...Page 105 Operation colorSENSOR CFO Fig 49 Trigger input window Fig 50 Example Level High No function After selecting a trigger input click the Apply button to activate the selected trigger event...

Page 106: ...cted by the sensor is created for each trigger event Output color group Here the new color is learned to the color group with the selected output configuration regardless of whether this color group a...

Page 107: ...color table Fig 51 Differentiated list of functions Trigger Type Selection Meaning Level High H 1 or Low L 0 State is present at the input for a longer period H High is live and logical 1 L Low logica...

Page 108: ...soon as the selected edge is detected at the trigger input The sensor executes the parameterized function when the trigger condition is fulfilled The duration of the pulse must be at least 5 s U I t F...

Page 109: ...lly switched for Color not recognized can be set in the Detection profile see 5 6 3 2 The outputs to be physically switched for the recognized color can be set in the color table and the corre spondin...

Page 110: ...when color group is detected activated PNP Outputs OUT switch according to supply voltage V when color group is detected activated PUSH PULL Push pull outputs OUT switch to supply voltage V when color...

Page 111: ...R CFO 5 6 8 System Settings Go to menu Settings System settings System settings such as Language selection Switch user Ethernet settings Reset sen sor and Update firmware are set under this menu item...

Page 112: ...lso be made via the menu bar see Fig 27 In the factory settings see A 2 the language selection is set to Browser This means that the web pages are always displayed in the language you have selected in...

Page 113: ...In the delivery state the Professional level is active After logging off the Professional you return to the User level For further settings you must log in again Assigning passwords prevents unauthor...

Page 114: ...colorSENSOR CFO Fig 59 Change password i A software update will not change the default password or a user defined password The Professional password is independent from Setup and is thus not loaded or...

Page 115: ...Protocol version four Here the address is structured as a 12 digit number separated by dots For sensors from MICRO EPSI LON the default IP address is 169 254 168 150 see Fig 60 Here you can change th...

Page 116: ...settings you have made Ethernet set tings IPv4 Method Static IP address Value When using a static IP ad dress it is necessary to enter the values for the IP address Gateway and Subnet mask this is not...

Page 117: ...its The first 64 bits form the so called prefix the last 64 bits con sist of a unique interface identifier The IPv6 address usually consists of 32 hexadecimal digits The address from example see Fig 6...

Page 118: ...ed for parameter setting of the measuring system via the web pages or via the API command set see A 3 but also enables non real time data transfer packet based data transfer The color values for measu...

Page 119: ...gs on the controller e g controller settings colors Ethernet settings can be permanently stored in user programs so called parameter sets During programming all settings are saved in the controller re...

Page 120: ...er or to send to support in case of problems i The exported file contains all sensor settings learned color values in the color table Click the Export button to export the settings to a file Import Th...

Page 121: ...elated to the detection profile color table interface configuration You can find the factory defaults in the appendix see A 2 i After resetting the controller is assigned a fixed IP Communication with...

Page 122: ...ect your firmware file Now click on the Update firmware button i The firmware update may take up to 15 minutes Please keep the browser window in the foreground Do not disconnect the colorSENSOR from t...

Page 123: ...y back on Keep the keys pressed for 2 seconds and then release them as soon as the LEDs start flashing The controller then starts resetting to factory defaults see A 2 During this operation all contro...

Page 124: ...ular intervals Dry Cleaning This can be accomplished with an anti static lens brush or by blowing off the lens with dehumidified clean oil free compressed air Wet Cleaning Use a clean soft lint free c...

Page 125: ...nance of the product repairs or modifications by third parties the use of force or other handling by unqualified persons This limitation of liability also applies to defects resulting from normal wear...

Page 126: ...in the affected parts for repair or replacement If the cause of a fault cannot be clearly identified please send the entire test system to MICRO EPSILON Eltrotec GmbH Manfred W rner Stra e 101 73037 G...

Page 127: ...e g residual waste can or the yellow recycling bin and must be disposed of separately This avoids hazards to the environment due to incorrect disposal and ensures proper recycling of the old appliance...

Page 128: ...AB M12 8P Bu ge 5m PUR open Connection cable 5 m lang 11234718 CAB M12 8P Bu ge 5m PUR D open Connection cable 5 m long for use with drag chain 11234719 Ethernet cable CAB M12 4P St ge 2m PUR Cat5e RJ...

Page 129: ...12 5P St ge 5m PUR open Connection cable 5 m lang 11234728 CAB M12 8P St ge 5m PUR D open Connection cable 5 m long for use with drag chain 11234724 CAB M12 5P St ge 5m PUR D open Connection cable 5 m...

Page 130: ...ies colorSENSOR CFO Name Photo Description Article number Power supply PS2020 Power supply for top hat rail instal lation input 230 VAC output 24 VDC 2 5 A 2420062 PS2031 Plug in power pack 24V 24W 1A...

Page 131: ...ang Optional Accessories colorSENSOR CFO Name Photo Description Article number CFS Sensor Color Fiber Sensor CFS4 C20 Reflex sensor 10810568 Further sensors can be found in the catalog or are availabl...

Page 132: ...unting accessories CFO mounting adapter For fastening colorSENSOR CFO100 or CFO200 or as replacement for colorSENSOR LT 1 LC 10 and LT 1 ST 11234713 CFO DIN rail mount ing kit Accessory for CFO mounti...

Page 133: ...or mounting colorSENSOR CFO100 or CFO200 on standard mounting rail top hat rail TS35 11234763 Protective caps Protective cap M12 for cable box Protective cap for covering open unused connection socket...

Page 134: ...sories colorSENSOR CFO Name Photo Description Article number Additional information White standard White standard reflection 99 11234694 11234695 Vacuum feed through Vacuum feed through 10811916 C mou...

Page 135: ...well as selection of interface or after diagram is called in browser Primarily used interface Web diagram Color OUT SYS Digital I O Measuring program Color inspection Switching output Color not recogn...

Page 136: ...A 3 Interface Instructions The current Interface Instructions for the colorSENSOR CFO contains the interfaces REST API RS232 or USB Modbus The documentation is available at https www micro epsilon com...

Page 137: ......

Page 138: ...rner Stra e 101 73037 G ppingen Germany Tel 49 0 7161 98872 300 Fax 49 0 7161 98872 303 eltrotec micro epsilon com www micro epsilon com Your local contact www micro epsilon com contact worldwide X975...

Reviews: