GENER
AL
INFO
SPECS
MOUNTING
ST
AR
T UP
OPER
ATION
M
AINTENANCE
DIMENSIONS
HO
W
TO
ORDER
LOGISTICS
87
NDX VALVE CONTROLLER
9. sign
APPROVALS FOR HAZARDOUS AREAS (1/2)
U
cCSAus certifications:
Class I, Division 1, Groups A, B, C, and D; T4/T5/T6
Ex ia IIC T4/T5/T6 Ga
Class I, Zone 0 AEx ia IIC T4/T5/T6 Ga
Class I, Division 2, Groups A, B, C, and D; T4/T5/T6
Ex ic IIC T4/T5/T6 Gc
Class I, Zone 2 AEx ic IIC T4/T5/T6 Gc
T4: 40°C to +80°C; T5: 40°C to +65°C; T6: 40°C to +50°C
Applicable to 5. sign “0” or “2”
Class I, Division 2, Groups A, B, C, and D; T4/T5/T6, Enclosure
Type 4X
Ex nA IIC T4/T5/T6 Gc
Class I, Zone 2 AEx nA IIC T4/T5/T6 Gc
T4: 40°C to +70°C; T5: 40°C to +65°C; T6: 40°C to +50°C
Applicable to 5. sign “0”
T4: 40°C to +80°C; T5: 40°C to +65°C; T6: 40°C to +50°C
Applicable to 5. sign “2”
10. sign
APPROVALS FOR HAZARDOUS AREAS (2/2)
If approvals are selected for both signs 9. and 10.,
keep the order shown below;
e.g. XE type shall be selected instead of EX type.
N
No approval
X
ATEX and IECEx certifications
See 9. sign “X” for details
E
ATEX and IECEx certifications (Exd)
See 9. sign “E” for details
U
cCSAus certifications
See 9. sign “U” for details
C
NEPSI (China) certifications:
Ex ia IIC T4...T6 Ga
Ex ib IIC T4...T6 Gb
Ex ic IIC T4...T6 Gc
T4: 40°C to +80°C; T5: 40°C to +65°C; T6: 40°C to +50°C
Applicable to 5. sign “0” or ”2”
D
NEPSI (China) certifications (Ex d):
Ex d IIC T4/T5/T6 Gb
Ex d tD A21 IP66 T85°C/ T95°C
T4 or T113: 40°C…+85°C; T5 or T95: 40°C…+72°C; T6 or
T85: 40°C…+57°C
Applicable to 5. sign “2”
J
Japan certifications:
Ex d IIC T6...T4 Gb
Ex tb IIIC T85°C...T113°C Db
T4: 40°C to +85°C; T5: 40°C to +72°C; T6: 40°C to +57°C
Applicable to 5. sign “2”
K
KOSHA (Korea) certifications:
Ex d IIC T6...T4
T4: 40°C to +80°C; T5: 40°C to +65°C; T6: 40°C to +50°C
Ex tD A21 IP66 T*
T113°C: 40°C to +85°C, T95°C: 40°C to +72°C, T85: 40°C
to +57°C
Applicable to 5. sign “2”
11. sign
PNEUMATIC CONNECTIONS & GAUGES
0
Standard, 1/4 NPT, no gauges
1
1/4 NPT, gauges (block with 1/4 NPT t gauges)
2
G1/4, no gauges (block with G1/4 threads)
3
G1/4, gauges (block with G1/4 t gauges)
12. sign
VARIANT
N
Neles
C
Neles, Chinese ID plates (for nonapproval version)
L
Neles, without LUI (Local User Interface)
Applicable to 5. sign “1”
13. sign
DIAGNOSTICS
0
Standard diagnostics
1
Advanced diagnostics
Applicable to 5. sign ”1”
14. sign
RESERVED
0
None
15. sign
RESERVED
0
None
16. sign
RESERVED
0
None
17. sign
SHALL ALWAYS BE HYPHEN
18.-20. sign
PARTNER CODE
0
7
5
Partner 1
1
2
8
Partner 2
6
6
8
Partner 3
Special feature – shall not affect hazardous area approvals
NDX 2
5
1
2
T
G
-
N
N
0
N
0
0
0
0
-
0
0
0
Y SAMPLE MODEL CODE (char = 21)
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21
17 HOW TO ORDER INTELLIGENT VALVE CONTROLLER NDX
HO
W
TO
ORDER