Technical Specifications
Inputs
DOX3104
DOX3304
Channels
4
4
Input Coupling
AC, DC, GND
Input Impedance
1
MΩ ± 2 % || 20 pF ± 4 pF or 50 Ω ± 2 %
Maximum input voltage
300 V (DC+AC Pk = 300 Vmax) CATI (1 MΩ) or ≤5Vrms (50 Ω)
Channel to Channel
isolation
(Same sensitivity V/div on
both channels)
> 100:1 at 50 MHz
> 100:1 at 150 MHz
Probe Attenuation
1X, 10X
Probe compensation
factor
.1X, .2X, .5X, 1X, 2X, 5X, 10X, 20X, 50X, 100X, 200X, 500X, 1000X, 2000X, 5000X,
10000X
Vertical System
DOX3104
DOX3304
Vertical Sensitivity
2 mV/div to 10V/div (sequence 1-2-5)
Vertical Position Range
2mV/div to 100mV/div : ± 1V
102 mV/div to 1V/div : ± 1V
1.02V/div to 10V/div : ± 100V
Vertical Resolution
8 bit
Number of Channels
4
4
Analog Bandwidth
100 MHz
300 MHz
Single Shot Bandwidth
100 MHz
300 MHz
Bandwidth Flatness at
BNC input
DC - 10 % of nominal Bandwidth : ± 1 dB
10 % - 50 % of nominal Bandwidth: ± 2 dB
50 % - 100 % of nominal Bandwidth: + 2 dB / - 3 dB
Low frequency cutoff
(-3dB) AC input coupling
≤ 10 Hz
Noise: Pk-Pk
≤ 0,6 div. 10 Pk-Pk values average,
calibres 2mV to 10V/div
≤ 1,0 div. 10 Pk-Pk values average, (152mV/div ~ 198mV/div, 1.52V/div
~1,98V/div)
≤ 0,7 div. 10 Pk-Pk values average,
fine vertical sensitivity adjust
SFDR including harmonics
(measure with FFT)
≥ 35 dB (≥ 10mV/div) ; ≥ 30 dB (< 10mV /div)
DC gain precision for
a 6 div amplitude signal.
± 3.0 % : 5 mV/div. to 10 V/div. Fixe sensitivities
± 4.0 % : 2 mV/div. Fine adjust sensitivity
DC measurements
precision all Sensitivities :
≤ 100mV/div.
± [3 % * (|measure| + |offset|) + 1 % * |offset| + 0,2 div. + 2 mV]
DC measurements precison
all sensitivities :
>100mV/div.
± [3 % * (|mesure| + |offset|) + 1 % * |offset| + 0,2 div. + 100 mV]
Rise Time
< 3.5ns
< 1.2ns
Overshoot (Typical)
(pulse tr = 500ps)
< 10 % (with 50 Ohm
internal input impedance)
Skew between channels
(same sensitivity V/div)
< 200ps
< 200ps
Math
+, - , *, /, FFT
, d/dt, ∫dt, √
FFT
Window Type
: Hanning, Hamming, Blackman, Rectangular
Number of samples : 1024
Bandwidth Limit
20 MHz ± 40 %
(Note : The Bandwidth limit is less than 10 MHz when using a X1 probe)
The oscilloscope must have been operating continuously for thirty minutes within the
specified temperature. You must perform the « Do Self Cal » operation through the
“Utility”
menu, if the operating temperature changes by more than 5°C. The oscilloscope must be
within the calibration interval. All specifications are guaranteed unless note "typical"