PAT Appliances & Machines Safety Trainer
AD 3
– MI 3399
242
5.4 Portable appliance of class 1
– IEC cord
Simulates
Error value
Error off
Error on
Simulation between contacts
Measurement
taken
Error off
Error on
Error 1
Loose contact of PE conductor
Error value
0,02 Ω
0,84 Ω
PE pin on socket (1) and PE pin
on socket (2)
Earth Bond
0,02 Ω
0,84 Ω
Error 2
Insulation fault
Error value
>20 MΩ
106 kΩ
L and PE pins on socket (2)
Insulation 500 V
DC
>20 MΩ
0,106 MΩ
Error 3
Crossed L and N wire
Polarity
/
L,
N
crossed
Polarity
Polarity
/
“L,
N
crossed”
Table 5-3: Description of simulated faults / relevant tests
Note:
For safety reasons there is a serial resistance between L/N pins of socket 1 and socket
2. Some test instruments can therefore return a fail on the Polarity test!