MI 2792 PowerQ4 Plus
Technical specifications
129
6.2.15 Signalling
Measuring range
Resolution Accuracy
1 % U
N
om
< U
Sig
< 3 % U
N
om
10
mV
± 0.15 %
U
N
om
3 % U
N
om
< U
Sig
< 20 % U
Nom
10
mV
± 5 %
U
Sig
U
N
om
: Nominal current (RMS)
U
Sig
: Measured signalling voltage
6.2.16 Unbalance
Unbalance range
Resolution Accuracy
u
-
u
0
0.5 % ÷ 5.0 %
0.1 %
± 0.15 %
u
-(0)
i
-
i
0
0.0 % ÷ 17 %
0.1 %
± 1 %
i
-(0)
6.2.17 Time and duration uncertainty
Real time clock (RTC) uncertainty
Operating range
Accuracy
-20
C ÷ 70
C
± 3.5 ppm
0.3 s/day
0
C ÷ 40
C
± 2.0 ppm
0.17 s/day
Event duration and recorder time-stamp and uncertainty
Measuring
Range
Resolution
Error
Event Duration
30 ms ÷ 7 days
1 ms
1 cycle
6.2.18 Temperature
Measuring range
Resolution
Accuracy
-10.0
C ÷ 85.0
C ±
0.5
C
-20.0
C ÷ -10.0
C and 85.0
C ÷ 125.0
C
0.1
C
± 2.0
C