MI 2792 PowerQ4 Plus
Operating the instrument
31
Harmonics / interharmonics components for phase L1
Harmonics / interharmonics components for phase L2
Harmonics / interharmonics components for phase L3
Harmonics / interharmonics components for neutral channel
Summary of components on all phases
Harmonics / interharmonic components for phase-to-phase
voltages
Switch to METER view
Switch to BAR view
Switch to TREND view (available only during recording)
Shift through harmonic / interharmonic components
Exit from “HOLD” screen without saving.
Return to the “MEASUREMENTS” menu screen.
3.5.2 Histogram (Bar)
Bar screen displays dual bar graphs. The upper bar graph shows voltage harmonics
and the lower bar graph shows current harmonics.
Figure 3.23: Harmonics histogram screens
Description of symbols and abbreviations used in BAR screens are shown in table
bellow.
Table 3.19: Instrument screen symbols and abbreviations
Current recorder status:
RECORDER is active
RECORDER is busy (saving data to memory)
RECORDER is not active
Current instrument time
Show selected harmonic / interharmonic component
Up, Un
p:1..3
True effective phase or line voltage U
Rms