MI 2792 PowerQ4 Plus
Introduction
9
Cos
,
DPF
Displacement factor including Cos
p
/ DPF
p
(phase p displacement
factor). See 5.1.5 and 5.1.6 for definition.
eP
+
, eP
-
Active energy including eP
p
(phase p energy) and eP
tot
(total energy).
Minus sign indicates generated energy and plus sign, indicate consumed
energy. See 5.1.7 for definition.
eQ
i+
,
eQ
c+
,
eQ
i-
, eQ
c-
Reactive energy including eQ
p
(phase p energy) and eQ
tot
(total energy).
Minus sign indicates generated energy and plus sign, indicate consumed
energy. Inductive reactive energy character is marked with “i”
and
capacitive reactive energy character is marked with “c”. See 5.1.7 for
definition.
eS
+
,
eS
-
Apparent energy. Minus sign indicates generated energy and plus sign,
indicate consumed energy. See 5.1.7 for definition.
f, freq
Frequency, including freq
U12
(voltage frequency on U
12
), freq
U1
(voltage
frequency on U
1
and freq
I1
(current frequency on I
1
). See 5.1.4 for
definition.
i
-
Negative sequence current ratio (%). See 5.1.11 for definition.
i
0
Zero sequence current ratio (%). See 5.1.11 for definition.
I
+
Positive sequence current component on three phase systems. See
5.1.11 for definition.
I
-
Negative sequence current component on three phase systems. See
5.1.11 for definition.
I
0
Zero sequence current components on three phase systems. See 5.1.11
for definition.
I
½Rms
RMS current measured over each half period , including
I
p
½
Rms
(phase p
current),
I
N½Rms
(neutral RMS current)
I
Fnd
Fundamental RMS current Ih
1
(on 1
st
harmonics), including
I
pFnd
(phase p
fundamental RMS current) and
I
NFnd
(neutral RMS fundamental current).
Ih
n
n
th
current RMS harmonic component including I
p
h
n
(phase p; n
th
RMS
current harmonic component) and I
N
h
n
(neutral n
th
RMS current harmonic
component). See 5.1.8 for definition
Iih
n
n
th
current RMS interharmonic component including I
p
ih
n
(phase p; n
th
RMS current interharmonic component) and I
N
h
n
(neutral n
th
RMS current
interharmonic component). See 5.1.8 for definition
I
Nom
Nominal current. Current of clamp-on current sensor for 1 Vrms at output
I
Pk
Peak current, including
I
pPk
(phase p current) including
I
NPk
(neutral peak
current)
I
Rms
RMS current, including
I
pRms
(phase p current), I
NRms
(neutral RMS current).
P, P
+
,
P
-
Active power including P
p
(phase p active power) and P
tot
(total active
power). Minus sign indicates generated power and plus / no sign, indicate
consumed power. See 5.1.5 and 5.1.6 for definition.