MI 2883 Energy Master
Introduction
15
PFe
totcap
Minus
sign
indicates
generated power and plus sign
indicates consumed power.
Suffix
ind/cap
represents
inductive/capacitive character.
This parameter is recorded
separately for each quadrant
as shown on figure.
P
lt
Phase long term flicker (2 hours), including
P
ltpg
(phase p
to phase g long term voltage flicker) and
P
ltp
(phase p to
neutral long term voltage flicker). See 5.1.9 for definition.
P
st
Short term flicker (10 minutes) including
P
stpg
(phase p to
phase g short term voltage flicker) and
P
stp
(phase p to
neutral voltage flicker). See 5.1.9 for definition.
P
st(1min)
Short term flicker (1 minute) including
P
st(1min)pg
(phase p
to phase g short term voltage flicker) and
P
st(1min)p
(phase
p to neutral voltage flicker). See 5.1.9 for definition.
P
inst
Instantaneous flicker including
P
instpg
(phase p to phase g
instantaneous voltage flicker) and
P
instp
(phase p to
instantaneous voltage flicker). See 5.1.9 for definition.
N
Instantaneous
combined
(fundamental
and
nonfundamental) nonactive phase power including
N
p
(phase p nonactive phase power). Minus sign indicates
generated and plus sign indicate consumed nonactive
power. See 5.1.5 for definition.
N
ind
N
cap
Recorded
phase
combined
(fundamental
and
nonfundamental)
nonactive
power including
N
cap/indp
(phase
p nonactive phase power).
Suffix
ind/cap
represents
inductive/capacitive character.
Minus sign indicates generated
and plus sign indicates consumed fundamental reactive
power. This parameter is recorded separately for each
quadrant as shown on figure. See 5.1.5 for definition.
Qfund
Instantaneous fundamental reactive phase
power
including
Q
p
(phase p reactive phase power). Minus sign
indicates generated and plus sign indicates consumed
fundamental reactive power. See 5.1.5 for definition.
270
0
PFe
totind
+
Le
ad
L
a
g
PFe
totcap
+
PFe
totcap
-
PFe
totind
-
180
0
90
0
0
0
+P
-P
-Q
+Q
I
II
III
IV
270
0
N
ind
+
Le
ad
L
a
g
N
cap
-
N
cap
+
N
ind
-
180
0
90
0
0
0
+P
-P
-Q
+Q
I
II
III
IV