MI 2883 Energy Master
Operating the instrument
65
SIGNALLING SETUP menu. See 3.19.4 for details.
START
Time when observed Signalling voltage crosses threshold
boundary.
MAX
Maximal voltage level recorder captured during signalling
events
Level
Threshold level in % of nominal voltage Un, defined in
SIGNALLING SETUP menu. See 3.19.4 for details.
Duration
Duration of captured waveform, defined in SIGNALLING
SETUP menu. See 3.19.4 for details.
f1
1
st
observed signalling frequency.
f2
2
nd
observed signalling frequency.
Table 3.53: Keys in Signalling (TABLE) screen
METER
Switches to METER view.
TREND
Switches to TREND view (available only during recording).
TABLE
Switches to TABLE view (available only during recording).
Moves cursor through signalling table.
Returns to the “MEASUREMENTS” submenu.
3.14 General Recorder
Energy Master has ability to record measured data in the background. By entering
GENERAL RECORDER option from RECORDERS submenu, recorder parameters can
be customized in order to meet criteria about interval, start time and duration for the
recording campaign. General recorder setup screen is shown below:
Figure 3.46: General recorder setup screen
Description of General recorder settings is given in the following table:
Table 3.54: General recorder settings description and screen symbols
General recorder is active, waiting for start condition to be
met. After start conditions are met (defined start time),
instrument will capture waveform snapshot and start
F4