4-9
1. This is a line voltage transformer, specific to
each different washers power input.
2. To remove the supply power transformer Lift
the cap off the wire connectors.
3. Use a Phillips head screwdriver to loosen
the wire retainers on the transformer.
4. The cap does not have to be removed to
loosen the wire retainers, there are holes to
access each retainer screw through the cap.
5. Remove the wires from the retainers.
6. Remove three Phillips head screws
securing transformer to the component tray.
7. Slide transformer toward the front of
the washer to remove the tab on the
transformer from slot in the component tray.
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before
operating.
SuppLY pOWer TranSFOrMer
Connector
Cap
Three Phillips
Screws
Slot
Tab