4-24
1. To remove the Appliance control unit, open
the control panel (See page 4-18).
2. Press the locking tab and disconnect the
wire harness connections to the ACU
3. To remove the water level pressure hose,
use a pair of needle nose pliers to squeeze
the clamp and move it down the hose.
4. Pull the hose off the connection with a slight
twisting motion.
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before
operating.
appLianCe COnTrOL uniT - reMOvaL
Hose
Clamp
One T-20
Screw
5. Remove one T-20 screw securing the ACU
board to the control panel bracket.
6. Pull the board forward, away from the
control panel bracket, and slide it to the left
to remove the tab from the slot at the other
end of the board.
7. Lift the locking tab and disconnect the door
lock wire harness connector.
8. Remove the board from the control panel.
Slot For
Tab
Summary of Contents for MYR20