![Maytag Commercial MYR20 Service Manual Download Page 44](http://html.mh-extra.com/html/maytag-commercial/myr20/myr20_service-manual_1751234044.webp)
4-20
1. To remove the coin drop, open the control
2. Press the locking tab and disconnect the
coin drop from the coin one connector.
3. Cut the wire tie securing the coin drop
wire harness in the control panel. Make
sure to replace any cut wire ties during
reinstallation.
4. Remove four 7/32” hex nuts securing the
coin drop to the control panel.
5. There is a nut, star washer and flat washer.
It may be easier to use a magnet to remove
the washers.
6. Push the coin drop out the front of the
control panel to remove it.
7. There is a card reader connector near the
coin drop connectors.
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before
operating.
COin DrOp
Coin Drop
Connector
Wire Tie
Card Reader
Connector
Coin Drop
Connector
Summary of Contents for MYR20
Page 6: ...vi NOTES ...
Page 10: ...1 4 Data plate location Data Plate On Back Panel ...
Page 13: ...2 1 Information specifications Rigid model dimensions ...
Page 24: ...3 6 NOTES ...
Page 70: ...4 46 NOTES ...
Page 80: ...6 2 Diagnostic cycle chart ...
Page 84: ...6 6 NOTES ...
Page 86: ...7 2 NOTES ...
Page 88: ......