4-38
1. To remove the drive belt, remove the back
2. Pull the belt away from the washer while
turning the basket pulley to roll the belt off
the basket pulley.
3. Remove the belt from the motor pulley.
1. To remove the temperature sensor, remove
the back panel (See page 4-36).
2. Press the locking tab and disconnect the
wire harness from the temperature sensor.
3. Grasp the temperature sensor and use a
twisting motion while pulling the temperature
sensor out of the rubber grommet.
Drive BeLT
TeMperaTure SenSOr
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before
operating.
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before
operating.