Figure 9-1. RTC Block Diagram
9.2
RTC Alarm Functions
The RTC provides time-of
–
day and sub-second interval alarm functions. The time-of-day alarm is implemented by matching
the count values in the counter register with the value stored in the alarm register. The sub-second interval alarm provides
an auto-reload timer that is driven by the trimmed RTC clock source.