© Martin Engineering GmbH
18
M3699UK-11/13
Installation
Abb. 14: Adjusting the air tensioner
Conveyor belt width
(mm)
Required pressure
(bar)
400-500
0.9
500-650
1.1
650-800
1.2
800-1000
1.4
1000-1200
1.6
1200-1400
1.7
1400-1600
1.9
1600-1800
2.0
1800-2000
2.3
2000-2200
2.6
2200-2400
2.9
2400-2600
3.1
2600-2800
3.3
2800-3000
3.5
Tab. 3: Recommended values of compressed air
Operator side
Back side
Compact controller unit
of the air tensioner
Pressure gauge
Housing
Lockable ballcock
External compressed air connection
with automatic bleeding