118
41-621.1 HART
®
to Modbus
®
Adaptor Operating Manual
R.
E3 Modulevel Modbus Registers
HART parameter
Modbus Register Info
Modbus Register number
Data
type
Number
Type
Device
Mode
HMA Mode
Slave
1
Slave
2
Slave
3
Slave
4
Slave
5
PV value
Float
2
Input
1302
1302 1312 1322 1332 1342
PV units code
UINT8
1
Input
104
104
124
144
164
184
Command 48 status bytes
UINT8
4
Input
1101-
1104
1101-
1104
1111-
1114
1121-
1124
1131-
1134
1141-
1144
Serial Number
UINT8
6
Input
2100
2100 2200 2300 2400 2500
Software version
UINT8
4
Input
2112
2112 2212 2312 2412 2512
Reserved/Unused
Trim Level
Float
2
Holding
3100
3100 3200 3300 3400 3500
Level Unit
Code
UINT16
1
Input
2140
2140 2240 2340 2440 2540
Process SG
Float
2
Holding
3102
3102 3202 3302 3402 3502
Trim SG
Float
2
Holding
3104
3104 3204 3304 3404 3504
Reserved/Unused
Password
UINT16
1
Holding
3120
3120 3220 3320 3420 3520
Operating Temperature
UINT16
1
Holding
3122
3122 3222 3322 3422 3522
Temperature units code
UINT8
1
Input
2160
2160 2260 2360 2460 2560
Summary of Contents for Jupiter JM4
Page 2: ......