41-621.1 HART
®
to Modbus
®
Adaptor Operating Manual
115
O.
Model RX5 Modbus Registers
HART parameter
Modbus Register Info
Modbus Register Number
Data
Type
Number
Type
Device
Mode
HMA Mode
Slave
1
Slave
2
Slave
3
Slave
4
Slave
5
PV value
1302
1302 1312 1322 1332 1342
PV units code
UINT8
1
Input
104
104
124
144
164
184
Command 48 status bytes
UINT8
1
Input
1101
1101 1111 1121 1131 1141
Serial Number
UINT8
6
Input
2100
2100 2200 2300 2400 2500
Software version
UINT8
6
Input
2112
2112 2212 2312 2412 2512
Reserved/Unused
Blocking Distance
Float
2
Holding
3100
3100 3200 3300 3400 3500
Level Unit
code
UINT8
1
Input
2140
2140 2240 2340 2440 2540
Level Offset
Float
2
Holding
3102
3102 3202 3302 3402 3502
Level Unit code
UINT8
1
Input
2141
2141 2241 2341 2441 2541
Distance
Float
2
Input
2150
2150 2250 2350 2450 2550
Echo Strength
Float
2
Input
2153
2153 2253 2353 2453 2553
Reserved/Unused
Password
UINT16
1
Holding
3120
3120 3220 3320 3420 3520
Reserved/Unused
Dielectric Range
code
UINT8
1
Holding
3130
3130 3230 3330 3430 3530
Turbulence
code
UINT8
1
Holding
3131
3131 3231 3331 3431 3531
Rate of Change
code
UINT8
1
Holding
3132
3132 3232 3332 3432 3532
Foam
code
UINT8
1
Holding
3133
3133 3233 3333 3433 3533
Summary of Contents for Jupiter JM4