* Initial value is determined by O02.04 (kVA Selection)
** This value is automatically set during auto tuning
Parameter
Name
Function
Range
Default
E02.01
Motor Rated FLA
Motor-rated current full load amps
0.01–70.0 A
*
E02.02
Motor Rated Slip
Motor-rated slip frequency
0.00–20.00 Hz
**
E02.03
No-Load Current
Motor no-load current
0.0–70.0 A
**
E02.04
Number of Poles
Number of poles in motor
02–48
04
E02.05
Terminal Resistance
Motor terminal resistance
0.000–65.000
Ω
**
E02.06
Leakage Inductance
Motor Leakage Inductance
0.0–40.0%
**
E02.07
Saturation Comp 1
Core-Saturation Compensation
Coefficient 1
0.00–0.50
**
E02.08
Saturation Comp 2
Core-Saturation Compensation
Coefficient 2
0.00–0.75
**
E02.09
Motor Mechanical Loss
Mechanical Torque Loss as a % of
motor torque
0.0–10.0%
0.0
E02.10
Motor Iron Loss of Torque
Compensation
Motor iron loss
0–65535 W
**
E02.11
Motor Rated Power
Motor rated power output
0.0–20.0 HP/kW
**
E02.12
Saturation Comp 3
Core-Saturation Compensation
Coefficient 3
1.30–5.00%
**