IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 161
H05.02
Series Baud Rate
03
00–08
-
00: 1200 bps
01: 2400 bps
02: 4800 bps
03: 9600 bps
04: 19200 bps
05: 38400 bps
06: 57600 bps
07: 76800 bps
08: 115200 bps
H05.03
Communications - Parity
00
00–02
-
00: No Parity
01: Even Parity
02: Odd Parity
H05.04
Communication - Error Stopping Method
04
00–04
-
00: Decel to Stop
01: Coast to Stop
02: Fast-Stop
03: Alarm Only
04: Use B03.03
H05.05
Communication - Error Detection Select
01
00–01
-
00: Disable
01: Enable
H05.06
Transmit Wait Time
05
05–65
ms
H05.07
RTS Control Select
01
00–01
-
00: Disable
01: Enable
H05.09
Communication - Error Detection Time
2.0
0.0–10.0
sec
H05.10
Output Voltage Reference
00
00–01
-
00: 0.1V
01: 1V
H05.11
Communication Enter Function Select
00
00–01
-
00: Enter Command must be used
01: Enter Command Not Required
H05.12
Run Command Method Selection
00
00–01
-
00: Bit 0 = Start/Stop Forward Direction
Bit 1 = Start/Stop Reverse Direction
01: Bit 0 = Start/Stop
Bit 1 = Forward/Reverse Direction
Parameter
Parameter Name
Default
Range
Units
Page