IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 80
5.3.2 Automatic Slip Compensation
As the load becomes larger, the motor speed is reduced and the motor slip increases. The slip compensation
function keeps the motor speed constant under varying load conditions. D02.01 sets the slip compensation gain.
When the gain is “1.0”, the output frequency is increased by 1% of the E01.06 setting at rated current. A setting of
“0.0” results in no slip compensation.
Parameter
Name
Function
Range
Default
D01.08
Magnetic Flux Compensation
Sets the magnetic flux compensation as
a percentage of the no load current value
(E02.03).
0000–1000
0000
D01.15
Mechanical Weakening
Detection Speed Level
Changes the DC Injection braking reference
one second after start.
Disabled when set to zero.
000–100%
050
Parameter
Name
Function
Range
Default
D02.01
Slip Compensation Gain
Slip compensation multiplier.
0.0–2.5
1.0 (OLV)
0.0 (V/f)
D02.02
Slip Compensation Time
Slip compensation primary delay time
0–10000 ms
200 (OLV)
2000 (V/f)
D02.03
Slip Compensation Limit
Slip compensation limit
0–250%
200
D02.04
Slip Compensation Regen
Slip compensation during regeneration
00, 01
00
00 Disabled
01 Enabled
D02.05
Slip Compensation V/f
Slip Compensation at V/f setting
00, 01
00
00 Include
01 Exclude
D02.06
Magnetic Flux
Characteristic
Magnetic Flux Characteristic Calculation
00, 01
00
00 Include
01 Exclude