Setting Motor Full Load Amps:
Locate the nameplate on your motor to find the Full Load Amps (FLA), and the motor RPM.
Press the
key once to move the cursor to the left most spot. Use the
and
keys to navigate
to the “E” menu. The display should show E01.01.
Press the
key once to move the blinking digit to the right.
Press the
key once to change from E01 to E02. The display now shows E02.01 (Motor FLA). Press
twice.
NOTE:
If more than one motor is being controlled by the VFD, enter in the total of all the motor full load amp
ratings. This step is important to provide proper motor overload protection.
Use the
,
, and
keys to enter the FLA from the motor nameplate.
Press
to save your changes. The display will temporarily show ,
then
E02.01.
Press
four times to return to the frequency reference display.
Your VFD is now ready.