LvSwitch IPPBX 3000 Manual
24
orange
green
blue
brown
1. Standard network cable: also known as straight-through network cable, both ends of twisted pair cable
compressed by RJ45 connector are 568A or 568B standard twisted pair cables, used for connecting terminal
equipment (such as PC) to HUB or LAN Switch.
2. Intersecting network cable: the twisted pair cable compressed by RJ45 connector at both ends is standard
568A at one end and standard 568B at the other end, which is used for connecting terminal equipment (such
as PC) to terminal equipment. Users need to be able to make their own.
3. When connecting the device with other IP terminals, standard network cables are used. The connection
steps are as follows:
4. Step1: Connect the Ethernet cable to the Ethernet interface and another end to the device
5. Step2: When the power’s on please check the link indicator status. Once the link light’s on shows that the
connection is right.When the link indicator is off, please check the connection.
Please do not plug the phone line socket into any RJ45 network interface, or it will damage the device;
Use CE standard Ethernet cable with RJ45 connector.
2.8.2 Connect FXS/FXO port
The FXS/FXO port
is with RJ45 interface, and the 1-channel RJ45 interface corresponds to the
4-channel RJ11 interface on the side of terminal equipment. Among them, PIN1 and pin2 of RJ45 are 1-way
phone, PIN3 and 4 are 1-way phones, PIN5 and 6 are 1-way phones, and PIN7 and 8 are 1-way phones.
2.8.3 Connect E1/T1 interface
The E1/T1 interface of the ippbx is RJ45 ,connect with 120
Ω
balanced twisted-pair cable. The cable
material of E1 wire is five kinds of network wire and super five kinds of network wire, and the two ends are
pressed together with RJ45 plug. The E1 cable configured for the equipment is the crossed E1 wire, cable
model E1-120ohm.
E1 line can be divided into cross line and straight line.
2.8.3.1 Intersection line
Cross wires are generally used to connect devices of the same level. When the E1 interface of the
opposite end device is also the RJ45 interface, cross E1 wires of 1, 4, 2 and 5 shall be used to connect. The
specific wiring relationship is shown in the following table.
Table 2-3 Cross line
A end
Cable chromatography
B end
1
White and orange
4
2
Orange
5
Summary of Contents for IPPBX3000
Page 1: ...LVswitch IPPBX3000 User Manual ...
Page 2: ...LvSwitch IPPBX 3000 Manual ii Version Product Version 1 6 0 1 Document Version A ...
Page 28: ...LvSwitch IPPBX 3000 Manual 26 ...
Page 170: ...LvSwitch IPPBX 3000 Manual 168 Mode Engineering staff background use the customer can not use ...
Page 193: ...LvSwitch IPPBX 3000 Manual 191 ...