93
Chapter 6. Function Description (FUN)
6.4.12 Overspeed error detection
l
Inverter detects error if motor rpm exceeds its limit. User can set the detection level and time of overspeed.
Code
LCD display
Description
Setting range
Unit
Factory setting
FUN_63
OverSpdLevel
Overspeed Detection Level
100.0 ~ 130.0
%
120.0
FUN_64
OverSpd Time
Overspeed Detection Time
0.00 ~ 2.00
sec
0.00
l
FUN_63 is based on 100% of FUN_04(Max Speed).
l
When motor speed exceeds FUN_63 (Overspeed Detection Level) and FUN_64(Overspeed Detection Time) elapses,
overspeed error detection is activated.
l
If FUN_64 is set to 0.00(sec) and motor rpm exceeds FUN_63, inverter immediately detects overspeed error.
6.4.13 Battery Operation (* For additional details, request for user manuals)
Code
Loader display
Description
Setting range
Unit
Factory Setting
FUN_65
Batt. Speed
Battery operation speed
2.5 ~ 200
rpm
50
FUN_66
Batt. Voltage
Battery input voltage
12 ~ PAR18
V
48
TIME
FX(or RX)
Motor
Speed
Target speed
Actual speed
ON
OFF
OFF
FUN_62(Restart Time)
ON