Chapter 5. Function code Table
5-10
Setting data
Function
code
Function name
LCD
display
Range
Unit
Default
Adjustment
during run
Page
FUN_53
Hold Time
Hold Time
100 ~ 10000
ms
1000
No
6-47
FUN_54
Electronic
thermal
selection
ETH Select
No/Yes
No
Yes
6-48~49
FUN_55
Electronic
thermal
level
for 1 minute
ETH 1 min
FUN_56 ~ 200
%
150
Yes
6-48~49
FUN_56
Electronic
thermal
level
for continuous
ETH Cont
50 ~ FUN_55
(available up to
150%)
%
100
Yes
6-48~49
FUN_57
Switching frequency
select
PWM Freq
2.5 ~ 10.0
kHz
8.0
No
6-49
FUN_58
Power
on
Run
selection
Power-on
Run
No
Yes
No
Yes
6-50
FUN_59
Restart after fault
reset
RST Restart
No
Yes
No
Yes
6-50
FUN_60
Number
of
auto
restart try
Retry
Number
0 ~ 10
0
Yes
6-50~51
FUN_61
Delay time before
Auto restart
Retry Delay
0.0 ~ 60.0
sec
1.0
Yes
6-50~51
FUN_62
Wait time for Restart
upon Stop
Restart Time
0.00 ~ 10.00
sec
0.00
No
6-51~52
FUN_63
Overspeed Detection
Level
OverSpdLev
el
100.0 ~ 130.0
%
120.0
No
6-51~52
FUN_64
Overspeed Detection
Time
OverSpd
Time
0.00 ~ 2.00
sec
0.00
No
6-51~52
FUN_65
Batter
operation
speed
Batt. Speed
2.5 ~ 200
rpm
50
No
6-52
FUN_66
Batter input voltage
Batt. Voltage
12 ~ PAR18
V
48
No
6-52
Notice 1)
FUN_55, 56 will display when setting FUN_54 as “YES”.