81
Chapter 6. Function Description (FUN)
6.4 Function group (FUN_[][])
6.4.1 Jump code (FUN_00)
Jumping directly to any parameter code can be accomplished using FUN_00 [Jump code].
Press [PROG] key first and set 2 using [
▲
(Up)], [
▼
(Down)], [SHITF/ESC] and press [ENT] key to jump to FUN_02. If
the desired code cannot be accessed or void, it automatically jumps to closest code.
After jumping, it is available to jump to other codes using [
▲
(Up)], [
▼
(Down)].
6.4.2 Operating method select
1) FUN_01(RUN/STOP source select)
There are four methods for issuing RUN/STOP command of the motor.
l
Terminal 1/ Terminal 2: Digital input of the FX/RX terminal
l
Keypad: [FWD], [REV], [STOP] key on the keypad
l
Option: using Option card. (Factory setting: Terminal 1)
Code
LCD display
Description
Setting range
Unit
Factory
setting
FUN_01
Run/Stop Src
RUN/STOP source select
Terminal 1
Terminal 2
Keypad
Option
Terminal 1
Difference between Terminal 1 and Terminal 2 setting
Run/Stop source select
Terminal ON/OFF
FWD/REV select
ON
FWD run command
FX
OFF
Stop command
ON
REV run command
Terminal 1
RX
OFF
Stop command
ON
Run command
FX
OFF
Stop command
ON
REV rotation
Terminal 2
RX
OFF
FWD rotation
For Analog speed setting, applying (+) Voltage marks FWD Run command and (-) voltage REV Run command.
Analog speed setting
range
FX / FWD / Option FWD
RX / REV / Option REV
0 ~ +10 V
Forward direction
Reverse direction
-10 ~ 0 V
Reverse direction
Forward direction
FUN
▶
Spd Ref Sel
02 Analog