83
Chapter 6. Function Description (FUN)
P1
P2
P3
P4
Setting speed
OFF
OFF
OFF
OFF
Speed command source is selected at FUN_02.
(One of analog inputs, FUN_12 and Option board)
ON
OFF
OFF
OFF
FUN_13
OFF
ON
OFF
OFF
FUN_14
ON
ON
OFF
OFF
FUN_15
OFF
OFF
ON
OFF
FUN_16
ON
OFF
ON
OFF
FUN_17
OFF
ON
ON
OFF
FUN_18
ON
ON
ON
OFF
FUN_19
X
X
X
ON
FUN_20 (JOG speed command)
The values of the multi-step speed command are shown below.
Code
LCD display
Description
Setting range
Unit
Factory
setting
FUN_12
Speed 0
Multi-step speed 0
0.0 ~ FUN_04
rpm
0.0
FUN_13
Speed 1
Multi-step speed 1
0.0 ~ FUN_04
rpm
0.0
FUN_14
Speed 2
Multi-step speed 2
0.0 ~ FUN_04
rpm
0.0
FUN_15
Speed 3
Multi-step speed 3
0.0 ~ FUN_04
rpm
0.0
FUN_16
Speed 4
Multi-step speed 4
0.0 ~ FUN_04
rpm
0.0
FUN_17
Speed 5
Multi-step speed 5
0.0 ~ FUN_04
rpm
0.0
FUN_18
Speed 6
Multi-step speed 6
0.0 ~ FUN_04
rpm
0.0
FUN_19
Speed 7
Multi-step speed 7
0.0 ~ FUN_04
rpm
0.0
FUN_20
Jog Speed
JOG speed
0.0 ~ FUN_04
rpm
100.0
l
FUN_04: Max. motor speed
3) FUN_21(Dwell Speed), FUN_22(Dwell Time)
Acceleration is instantly stopped and restarted before driving a heavy load such as hoists when selected.
Code
LCD display
Description
Setting range
Unit
Factory
setting
FUN_21
Dwell Speed
Dwell Speed
0.0 ~ FUN_04
rpm
100.0
FUN_22
Dwell Time
Dwell Time
0.00 ~ 100.00
sec
0.00
l
FUN_04: Maximum motor speed
l
Disabled when FUN_22 is set to “0”.
Speed
FUN_21
FUN_22
Time
RUN