103
ACCESSORIES INSTALLATION
ENGLISH
Solar pump
Solar pump can be required to energize water flow when solar thermal system is installed.
How to install solar pump
Follow below procedures step 1 ~ step 4.
Step 1. Check if the power of the unit is turned off.
Step 2. Disassemble front panels and distinguish control box(Indoor) of the unit.
Step 3. Check if the harness(Black) is inserted fully to the indoor unit PCB (CN_W_PUMP_B).
Step 4. Connect the external pump to terminal block 1(4/5).
h
It is possible to un-use solar pump depending on installation environment.
L
N
BR
BL
6
7
WATER PUMP
(B)
CN_W_PUMP_B
Solar pump
AC 230 V
Indoor PCB
h
The terminal block connection number may differ depending on the model. Refer to the
“Wiring Diagram” in the SVC Manual.
- For 3 Series
- For 4 Series
L
N
15
16
WATER PUMP
(B)
CN_PUMP_A4
Solar pump
AC 230 V
Indoor PCB
CAUTION
!
When connecting a pump of 1.05A or higher, its output must be used as a signal line only.