32
GENERAL INFORMATION
ENGLISH
CASE 4-1: Connecting 2nd Circuit (For 3 Series)
Floor heating loop
Mix
2
nd
circuit temp. sensor
Mix Kit
[Circuit 1] Direct Circuit
[Circuit 2] Mixing Circuit
Floor heating loop
Radiator
Radiator
M / F
Buffer
Tank
R
T
Outdoor
Indoor
CASE 4-2: Connecting 2nd Circuit (For 4 Series)
[Circuit 1] Direct Circuit
Radiator
Radiator
Hydronic
separator
Floor
heating loop
Floor
heating loop
2
nd
circuit temp. sensor
Mix
Mix Kit
[Circuit 2] Mixing Circuit
M / F
Buffer
Tank
R
T
Outdoor
Indoor
High Temperature
Room Thermostat
(Field supply)
2way valve (Field supply)
By-pass valve(Field supply)
Low Temperature
Shut-off valve
Magnetic Filter (Mandatory)
Air vent (Field supply)
M / F
Pressure Regulation valve
(Field supply)
3way valve
(Field supply)
Pump(Field supply)
Mix Kit (Field supply)
NOTE
• Mix Kit
- You can install it when you want to set the temperature of two rooms individually
- When heating, Circuit 2 can not be higher than Circuit 1.
- When cooling, Circuit 2 can not be lower than Circuit 1.
- The types and specifications of the Mix Kit are to comply with
Installation