Select a circuit breaker and power cable suitable for the current specification.
The power cable connected to the unit should be complied with IEC 60245 or HD 22.4 S4 (This
equipment shall be provided with a cable set complying with the national regulation.
Pipes and wires should be purchased separately for installation of the product.)
a These cords may only be used if their length does not
exceed 2 m between the point where the cord or
cord guard enters the appliance and the entry to the
plug.
b Cords having the cross-sectional areas indicated in
the parentheses may be used for portable appliances
if their length does not exceed 2 m.
CAUTION
!
GN/
YL
20 mm
35±5 mm
10±3 mm
For the 1-Phase
20 m
m
GN
/YL
35±5 mm
10±3 mm
For the 3-Phase
Power cable
(Type : H07RNF)
Current [A]
Area [mm
2
]
[A]
≤
0.2
Tinsel cord
a
0.2< [A]
≤
3
0.5
a
3< [A]
≤
6
0.75
6< [A]
≤
10
1.0 (0.75)
b
10< [A]
≤
16
1.5 (1.0)
b
16< [A]
≤
25
2.5
25< [A]
≤
32
4
32< [A]
≤
40
6
40< [A]
≤
63
10
Factory Model Name
Buyer Model Name
Phase[Ø]
Capacity [kW]
ELCB
ZHBW056A0
HM051M U43
1
5
16 A
ZHBW076A0
HM071M U43
7
20 A
ZHBW096A0
HM091M U43
9
25 A
ZHBW096S0
HM091MRS U33
1
9
16 A
ZHBW126A0
HM121M U33
12
40 A
ZHBW146A0
HM141M U33
14
40 A
ZHBW166A0
HM161M U33
16
40 A
ZHBW128A0
HM123M U33
3
12
16 A
ZHBW148A0
HM143M U33
14
16 A
ZHBW168A0
HM163M U33
16
16 A
ZHBW056A1
HM051MR U44
1
5
16 A
ZHBW076A1
HM071MR U44
7
20 A
ZHBW096A1
HM091MR U44
9
25 A
ZHBW126A1
HM121MR U34
1
12
40 A
ZHBW146A1
HM141MR U34
14
40 A
ZHBW166A1
HM161MR U34
16
40 A
ZHBW128A1
HM123MR U34
3
12
16 A
ZHBW148A1
HM143MR U34
14
16 A
ZHBW168A1
HM163MR U34
16
16 A