86
ACCESSORIES INSTALLATION
ENGLISH
• For the following cases, separately purchase and use the cables suitable for the situation.
- Do not install the cable over 50 m.(It may cause communication issues.)
- If the distance between the wired remote controller and the unit is 10 m or more : 10 m
extension cable (model name: PZCWRC1)
Indoor PCB
CN_REMO
NOTE
Indoor terminal block
RED(12V)
YL(SIGNAL)
BR(GND)
Indoor MAIN PCB
Wired controller
Extension Cable
Check whether the connector
is connected correctly.
Check whether the connector
is connected correctly.
OK
During the wired remote controller installation, do not bury it in the wall. (It may cause
temperature sensor failure.)
Do not install the cable over 50 m. (It may cause communication defect.)
When you install the extension cable, carefully check the direction of the connectors on the
remote controller side and the product side before the installation.
Specification of extension cable: AWG 24, 3 conductor or above.