87
ACCESSORIES INSTALLATION
ENGLISH
Cable connection method to use external device
1) Wired remote controller-cable connection method.
- In the wired remote controller, connect the part marked in the following figure (J02C, DO-
Port) to the cable.
- According to the installation environment, there are 3 directions (Rear entry, top side, and
right side) for the installation.
2) Cable extension connection method
- Among the cables connected to the wired remote controller, cut the remaining connectors
on the other side, and then extend and connect the cables
- Extension cable specification: 24~26 AWG.
CAUTION
For the External device connection, use the cable insulated with sheath for the extension
connection.
Before combining with the installation plate, arrange the cables to avoid interference with the
internal parts.
!
RMC
DO-Port
2 (GND_Black)
3 (DC 12 V_Red)
Field connection
30 cm
• Output specification
- Voltage : DC 11~12 V
- Current : 5 mA
Remote
controller
product
composition