Select Temperature Sensor
The product can be operated according to air temperature or water temperature. The selection
for setting temperature as air temperature or water temperature is determined.
• In the installer setting list, Select Temperature Sensor category, and press [OK] button to move
to the detail screen.
NOTE
OK
• Set DIP switch No. 5 of option switch 2 to ‘ON’ in order to use remote temperature sensor.
• When the sensor location is set to Remote Control, the RS3 controller must be placed
inside of suitable Reference room.
Value
Default
Range
Control Standard
Water
Water / Air / Air + Water
Sensor Location
Remote Control
Remote Control / Indoor Unit