118
ACCESSORIES INSTALLATION
ENGLISH
Buffer
Tank
Filter
Collector
Collector
[Outdoor]
[Room]
[Mech. Room]
Remote
Control
2 Way Valve
(Manual)
Air vent
Floor Heating
Convector
Thermostatic Valve
T
s
2 Way Valve
(Signal)
Safety Valve
Backup
Heater
Product
Buffer
Tank
Filter
Collector
Collector
[Outdoor]
[Room]
[Mech. Room]
s
Cooling: Close
Heating: Open
Remote
Control
2Way Valve
(Manual)
Air vent
Floor Heating
Convector
Thermostatic Valve
T
s
2 Way Valve
(Signal)
[Outdoor]
Backup
Heater
s
(A) Cooling
3 Way Valve
(Signal)
Heating
▲
▲
(B)
Product
3 Way Valve direction
Flow A (Bypass) : Cooling
Flow B (Heater) : Heating
s
Floor h Backup Heater (Only Heating)
Floor h Con Backup Heater (H Cooling)
NOTE
• When the Backup Heater is installed in a
reversible system, condensation may occur
inside the Backup Heater.
• To provide a bypass for the condensate, install
3way valve.
• During cooling operation, connect the 3-Way
Valve using the 2-Way Valve connection
terminal to prevent water from going to the
Backup Heater
Typical Installation Example