Integrating the LES in the process control (Ethernet)
Leuze electronic
LES 36
99
TNT
35/7-2
4
V
75…76
Current Sequent Hits Left in EAW2
77…78
Current Sequent Hits Right in EAW2
79…80
Left edge X-value LX in EAW2
1)
81…82
Left edge Z-value LZ in EAW2
1)
83…84
Right edge X-value RX in EAW2
1)
85…86
Right edge Z-value RZ in EAW2
1)
87…88
Width W in EAW2
1)
89…90
Height H in EAW2
1)
91…92
Current Sequent Hits Left in EAW3
93…94
Current Sequent Hits Right in EAW3
95…96
Left edge X-value LX in EAW3
1)
97…98
Left edge Z-value LZ in EAW3
1)
99…100
Right edge X-value RX in EAW3
1)
101…102
Right edge Z-value RZ in EAW3
1)
103…104
Width W in EAW3
1)
105…106
Height H in EAW3
1)
107…108
Current Sequent Hits Left in EAW4
109…110
Current Sequent Hits Right in EAW4
111…112
Left edge X-value LX in EAW4
1)
113…114
Left edge Z-value LZ in EAW4
1)
115…116
Right edge X-value RX in EAW4
1)
117…118
Right edge Z-value RZ in EAW4
1)
119…120
Width W in EAW4
1)
121…122
Height H in EAW4
1)
123…180
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- The remaining user data are used for internal maintenance purposes of the
manufacturer.
1)
Unit: 1/10mm (0.1mm)
Byte
MSB
High-Byte LSB MSB Low-Byte
LSB Meaning of the bits