Integrating the LES in the process control (Ethernet)
Leuze electronic
LES 36
108
TNT
35/7-2
4
V
Querying whether median filter is active/not active
When using parameter ID 0x07DB, sensor control command 0x005B can be used to check
whether the median filter is activated.
When using sensor control command 0x005B with parameter ID 0x07DB, one word of user
data is transmitted to the sensor:
The sensor responds with 0x005C and returns one word of user data.
Set Single Inspection Task Parameter
Individual parameters of the active inspection task can be changed with sensor control
command 0x006D. The following parameters can be changed:
• Name of an inspection task,
• Operation Mode: Free Running or Input Triggered
• Enabling of activation (Activation Input: Regard or Disregard),
• Cascading Output: Enable or Disable,
• Exposure duration of the laser (Light Exposure)
• Detection range of the LPS (Field of View).
Byte
MSB
High-Byte
LSB MSB
Low-Byte
LSB Meaning of the bits
31…32
1
1
1
1
1
0
1
1
0
1
1 Parameter ID for median filter = 0x07DB
Byte
MSB
High-Byte
LSB MSB
Low-Byte
LSB Meaning of the bits
31…32
MF
MF=1
: median filter active
MF=0
: median filter inactive
Byte
MSB
High-Byte
LSB MSB
Low-Byte
LSB Meaning of the bits
31…32
SF
SF
= SaveFlag
33…34
Parameter ID for parameter selection
35…58
Parameter value[s] dependent on parameter ID