Display and control panel
Leuze electronic
LES 36
53
TNT
35/7-2
4
V
7.1.3
Indicators in the display
The display changes depending on the current operating mode. There are the following three
display modes:
• Alignment aid and status display
• Command mode
• Menu display
The menu display is accessed by pressing one of the two control buttons. Operation
of the LES via the menu is described in Chapter 7.2.2.
With PROFIBUS devices, the bus state is first displayed after power-on
(displayed for approx. 3s). If the PROFIBUS was detected, alignment
aid and status are then displayed.
Alignment aid
As an alignment aid, the current measurement value at the left edge
(
Lxxx
), in the middle (
Mxxx
) and at the right edge (
Rxxx
) of the detection
range is displayed in the OLED display in units of millimeters. If no object
is detected or if the distance is too small, distance value
000
(mm) appears in the display.
Align the Light section sensor by rotating it about the y-axis in such a way that the same
value is indicated for
L
,
M
,
R
.
Status indicator
Displayed on the second line of the display is the selected inspection
task (
Txx
), a measurement value as well as the current sensor state (see
chapter 4.2 "Operating the sensor").
The indication of the sensor state in the display has the following meaning:
•
fRun
= Free Running
•
Trig
= Triggering
•
!ACt
= Activation (laser on/off)
T12
means that Inspection Task 12 is currently active, for example. Value range:
T00
to
T15
.
Meaning of the measurement value display:
•
X-151
means that the X-coordinate of the right-most measurement point is at position
-151mm.
•
x 040
means that the X-coordinate of the left-most measurement point is at position
+40mm.
•
Z 600
means that the Z-coordinate of the right-most measurement point is at position
600mm.
•
Z 500
means that the Z-coordinate of the left-most measurement point is at position
+500mm.
•
W 230
means that the width of the object is 230mm.
•
H 059
means that the height of the object is 59mm.
Definition of the displayed measurement value:
• For analog sensors, the measurement value assigned to the analog output is displayed
in mm.
• For sensors with PROFIBUS, the measurement value assigned under
Edge 1 - Pro-
fibus Inputs 1
is displayed.
waiting for PB
L450 M450 R450
T00 X-151 fRun