Integrating the LES in the process control (Ethernet)
Leuze electronic
LES 36
110
TNT
35/7-2
4
V
Get Single Inspection Task Parameter
Individual parameters of the active inspection task can be output with sensor control
command 0x006F. The following parameters can be accessed:
• Name of the active inspection task
• Number of the active inspection task
• Operation Mode: Free Running or Input Triggered
• Setting of activation (Activation Input: Regard or Disregard)
• Setting of cascading output (Cascading Output: Enable or Disable)
• Exposure duration of the laser (Light Exposure)
• Detection range of the LES (Field of View).
Parameters and settings:
Sensor response:
The sensor responds with 0x0070 and returns 9 … 20 user data words.
Byte
MSB
High-Byte
LSB MSB
Low-Byte
LSB Meaning of the bits
31…32
Parameter ID which can be accessed
Parameter ID
Parameter meaning
0x0BB8
Number of the active inspection task
0x0BB9
Name of an inspection task
0x0BBA
Operating mode
0x0BBB
Enabling of activation
0x0BBC
Enabling of the cascading output
0x0BBD
Exposure duration of the laser
0x0BBE
Manual adjustment of the exposure duration
0x0BBF
X-coordinate detection range
0x0BC0
Z-coordinate detection range
Byte
MSB
High-Byte
LSB MSB
Low-Byte
LSB Meaning of the bits
31…32
Parameter ID for parameter selection
33…34
Data type:
1 = UINT8; 2 = UINT16, 5 = SINT16, 7 = CHAR
35…36
Number of parameter values (byte 47 and following)
37…38
Lower limit of parameter value (HighWord)
39…40
Lower limit of parameter value (LowWord)
41…42
Upper limit of parameter value (HighWord)
43…44
Upper limit of parameter value (LowWord)
45…46
No meaning
47…70
Parameter value(s) of accessed parameter ID