Integration of the LES 36…/PB in the PROFIBUS
Leuze electronic
LES 36
118
TNT
35/7-2
4
V
11.4
Overview of the GSD modules
The LES 36…/PB has one module slot. Select the corresponding module from the GSD to
set the process data of the LES 36…/PB that are to be transmitted. Several modules are
available for selection. Beginning with the simplest input module
M1
, additional inputs are
included with the subsequent modules. All available output data are already contained in
module
M1
. The modules with higher numbers the modules with the lower numbers
(example:
M2
contains
M1
and the extensions of
M2
).
Note!
As the module number increases, so too does the number of user data bytes that are to be
transmitted.
The maximum measurement rate of 100Hz can only be ensured up to module
M2
.
Therefore, only modules which contain the data actually required should be selected, i.e.
the smallest possible module number should be selected.
Note!
All input and output modules described in this documentation are described
from the view-
point of the control
:
Inputs (I) described are inputs of the control.
Outputs (O) described are outputs of the control.
Parameters (P) described are parameters of the GSD file in the control.
Output data (from viewing position of control)
Position
(bytes)
Name
Bits in byte
Value
range
Meaning
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
0
uTrigger
Trig_7
Trig_6
Trig_5
Trig_4
Trig_3
Trig_2
Trig_1
Trig_0 0 … 255 Triggering via PROFIBUS (in the case of changes)
1
uActivation
-
-
-
-
-
-
-
Act_On
0 … 1
Activation (=1) or deactivation (=0) of the sensor
2
uInspTask
-
-
-
IT_b3
IT_b2
IT_b1
IT_b0
0 … 15
Inspection task of PROFIBUS master and save flag (B7)
Table 11.1:
PROFIBUS - Overview of output data (from viewing position of control)