LESsoft configuration software
Leuze electronic
LES 36
79
TNT
35/7-2
4
V
Analysis Window Definitions
Here, you define the parameters for object detection in up to four EAWs and four AWs. Select
the check box in the
Active
column to activate object detection in the respective analysis
window. The optionally selectable object detection enables stable measurement results
even under problematic conditions.
In the
Current Hits
column, LESsoft displays the number of measurement points that
are detected in the analysis window. In the
Hits On
column, you define how many measure-
ment points must be detected in order for the evaluation result of the object detection to
be
ok
in the respective analysis window. If the result is
ok
, a green dot is displayed in the
Current Status
column. The state remains green until the number of detected hit points
becomes equal to or smaller than the value you set in the
Hits Off
column.
The entries in
Hits On
and
Hits off
thus let you configure a switching hysteresis to
prevent an (unwanted) change of the switching state under admissible changes in the object
position or other physical quantities.
The further processing and combination of results from object detection occurs by pressing
the
Edit Logical Combinations
button.
Note!
The changed settings must be transferred to the sensor with
Apply Settings
.