Troubleshooting and fault elimination
9-2
BA9300SU EN 2.1
Display via the LECOM status word C0150
Bit
Meaning
0
FREE 0
freely combinable
1
IMP (pulse inhibit)
0 = Pulses enabled for power stage
1 = Pulses inhibited for power stage
2
FREE 2
freely combinable
3
FREE 3
freely combinable
4
FREE 4
freely combinable
5
FREE 5
freely combinable
6
f
d
= 0 (actual speed value = 0)
0 = [n
≠
0]
1 = [n = 0]
7
RSP (controller inhibit)
0 = No controller inhibit
1 = Controller inhibit
hex
bin
0
0000
Unit initialisation
1
0001
Switch-on inhibit
3
0011
Operation inhibited (controller inhibit)
8-11
Controller status
6
0110
Operation enabled
7
0111
Message active
8
1000
Active fault
9
1001
Power off
A
1010
Fail-QSP
12
Warning
0 = No warning
1 = Warning
13
Meldung
0 = No message
1 = Message
14
FREE 14
freely combinable
15
FREE 15
freely combinable