Appendix
11-22
BA9300SU EN 2.1
Code
Important
Possible settings
LCD
Code
Important
Choice
Lenze
LCD
Lenze inverter motor in star connection
•
The temperature monitoring via resolver or encoder cable is
deactivated automatically, i.e.:
C0583 = 3
C0584 = 3
C0594 = 3
Lenze inverter motor in star connection
•
The temperature monitoring via resolver or
encoder cable is deactivated automatically,
i.e.:
C0583 = 3
C0584 = 3
C0594 = 3
210
DXRA071-12-50
211
DXRA071-22-50
212
DXRA080-12-50
214
DXRA090-12-50
215
DXRA090-32-50
216
DXRA100-22-50
217
DXRA100-32-50
218
DXRA112-12-50
219
DXRA132-12-50
220
DXRA132-22-50
221
DXRA160-12-50
222
DXRA160-22-50
223
DXRA180-12-50
224
DXRA180-22-50
DXRAXX071-12, f
d
: 50Hz
DXRAXX071-22, f
d
: 50Hz
DXRAXX080-12, f
d
: 50Hz
DXRAXX090-12, f
d
: 50Hz
DXRAXX090-32, f
d
: 50Hz
DXRAXX100-22, f
d
: 50Hz
DXRAXX100-32, f
d
: 50Hz
DXRAXX112-12, f
d
: 50Hz
DXRAXX132-12, f
d
: 50Hz
DXRAXX132-22, f
d
: 50Hz
DXRAXX160-12, f
d
: 50Hz
DXRAXX160-22, f
d
: 50Hz
DXRAXX180-12, f
d
: 50Hz
DXRAXX180-22, f
d
: 50Hz
Lenze inverter motor in delta connection
•
The temperature monitoring via resolver or encoder cable is
deactivated automatically, i.e.:
C0583 = 3
C0584 = 3
C0594 = 3
Lenze inverter motor in delta connection
•
The temperature monitoring via resolver or
encoder cable is deactivated automatically,
i.e.:
C0583 = 3
C0584 = 3
C0594 = 3
250
DXRA071-12-87
251
DXRA071-22-87
252
DXRA080-12-87
254
DXRA090-12-87
255
DXRA090-32-87
256
DXRA100-22-87
257
DXRA100-32-87
258
DXRA112-12-87
259
DXRA132-12-87
260
DXRA132-22-87
261
DXRA160-12-87
262
DXRA160-22-87
263
DXRA180-12-87
264
DXRA180-22-87
DXRAXX071-12, f
d
: 87Hz
DXRAXX071-22, f
d
: 87Hz
DXRAXX080-12, f
d
: 87Hz
DXRAXX090-12, f
d
: 87Hz
DXRAXX090-32, f
d
: 87Hz
DXRAXX100-22, f
d
: 87Hz
DXRAXX100-32, f
d
: 87Hz
DXRAXX112-12, f
d
: 87Hz
DXRAXX132-12, f
d
: 87Hz
DXRAXX132-22, f
d
: 87Hz
DXRAXX160-12, f
d
: 87Hz
DXRAXX160-22, f
d
: 87Hz
DXRAXX180-12, f
d
: 87Hz
DXRAXX180-22, f
d
: 87Hz
[C0087]
0OS RPFF'
3950
300
{1 rpm}
16000
Rated motor speed
Å
depends on C0086
•
Change of C0086 resets value to the
assigned default setting
[C0088]
0OS E855F1S
2.4
0.5
{0.1 A}
300.0
Rated motor current
Å
depends on C0086
•
Change of C0086 resets value to the
assigned default setting
[C0089]
0OS G5FQ8F1EW
140
10
{1 Hz}
1000
Rated motor frequency
[C0090]
0OS TOMSDHF
390
50
{1 V}
500
Rated motor voltage
Å
depends on C0086
•
Change of C0086 resets value to the
assigned default setting
[C0091]
0OS EOR PIJ
0.7
0.50
{0.01}
1.00
Motor cos
ϕ
Å
depends on C0086
•
Change of C0086 resets value to the
assigned default setting
C0093
'5JTF J'F1S
g
Controller identification
C0093
'5JTF J'F1S
g
0
invalid
1
none
93xx
93xx
Type of Lenze servo inverter
C0094
3DRRUO5'
0
0
9999
Password
Summary of Contents for EVS9321-CS
Page 3: ...Operating Instructions EDB9300UES 00414796 Global Drive 9300 servo ...
Page 21: ...Technical data 3 8 BA9300SU EN 2 1 ...
Page 57: ...Installation 4 36 BA9300SU EN 2 1 ...
Page 73: ...During operation 6 4 BA9300SU EN 2 1 ...
Page 117: ...Troubleshooting and fault elimination 9 10 BA9300SU EN 2 1 ...
Page 119: ...Maintenance 10 2 BA9300SU EN 2 1 ...
Page 188: ...Appendix 11 69 BA9300SU EN 2 1 ...
Page 189: ...Appendix 11 70 BA9300SU EN 2 1 ...