Installation
4-8
BA9300SU EN 2.1
•
Observe the following points to comply with the technical data:
– Ensure sufficient ventilation of the heat sink.
– The free space behind the control cabinet back panel must be at least 500 mm.
•
If you install several controllers in the control cabinet:
– Do not install the controllers on top of each other.
•
The cooling path must not exceed the thermal resistances in the table:
Controller
Cooling path
Type
Power to be dissipated P
loss
[W]
R
thmax heat sink
[K/W]
9321-Cx
80
0.50
9322-Cx
80
0.50
9323-Cx
100
0.40
9324-Cx
155
0.25
9325-Cx
210
0.19
9326-Cx
360
0.10
9327-Cx
410
0.09
9328-Cx
610
0.06
•
The temperature of the cold plate must not 85
°
C.
•
Penetration depth t of the screws into the basic plate of the controller:
8 mm
$
t
$
10 mm
•
For the bore pattern and surface quality of the heat sink please consult the factory.
•
Apply the heat conducting paste (accessory kit) to the cold plate of the controller.